CID-00396: Elbow, 200A, Loadbreak

Super-Class:
  200A, Loadbreak Seperable Cable Accessories
  Single Phase 200A Deadfront Padmount Switch Cubicle Structure
  Transformer Structure, 200A Wells, Loop Feed, Radial Connection, Single Phase, Deadfront, Padmount
  Junction Cabinet Loadbreak Cable Accessories
  Connection, Distribution, Primary, 200A Loadbreak, Assembly
  200A Parking Stand Arrester with 200A LB Elbow Assembly
  200A Bushing Arrester with 200A LB Elbow Assembly
  Connection Assembly, 200A, Deadfront, Medium Voltage, Transformer
  Transformer Structure, 200A Wells, Loop Open Point, Radial Connection, Single Phase, Deadfront, Padmount
Class Name: Elbow, 200A, Loadbreak
Sub-Classes:
Arc Quenching Probe
 
200A Loadbreak Elbow Housing
 
Lug, Elbow, Compression, 200A
 
Concentric Neutral Preperation, Underground Primary Cable, 200A Loadbreak Elbow
 
Elbow and Probe Preperation, Probe, 200A Loadbreak
 
Summary: A separable connector (elbow) is a fully insulated and shielded system for terminating and electrically connecting an insulated power cable to electrical apparatus, other power cables, or both, so designed that the electrical connection can be readily established or broken by engaging or separating the connector at the operating inte rface. Suitable for use on 26.4 kV, 4-wire, solidly-grounded systems and 5 kV systems. Because of high fault duty, connectors rated 200 A continuous are not appropriate for network systems. Network systems should be constructed with connectors rated 600 A (or 900 A) continuous

Summary

The 200A loadbreak seperable elbow connector is suitable for connecting URD underground cable to URD transformers and switchgear. It provides a deadfront submersible cable connection. These elbows are submersible so they are especially useful in all subway and subsurface transformer primary connections, and connections to various types of equipment such as vacuum switch and interrupters.

Loadbreak and load make operations require the aid of a live-line tool (shotgun stick with elbow puller).

For application on ungrounded WYE or delta systems, the next higher voltage class product is recommended, for instance on a 15KV delta, the 25KV elbow should be used. Their ratings are always line-to-line, so a 15kV elbow will only be rated 8.6KV Line-to-Ground, so a 15kV delta will exceed the rating of the elbow.

The elbows kits are cable size sensitive due to the elbow lug needs to be crimped to the connector, and the elbow housing needs to provide a water tight seal around the cable insulation. [1] [2]

Pictures

15kV

Elastimold Cooper Hubbell Richards Manufacturing
elastimold200A15elbow.png cooper200A15elbow.png hubbell200A15elbow.png richards200A15elbow.png
Available with a test point (capacitive), cable jacket sealing and/or shield grounding kit, compression copper lug, bi-metallic compression lug and CSA compression lugs Available with a test point (capacitive), cable jacket sealing and/or shield grounding kit, compression copper lug, bi-metallic compression lug, CSA compression lugs and 5kV Cable Adapter Available with a test point (capacitive), cable jacket sealing and/or shield grounding kit, compression copper lug, and bi-metallic compression lug Available with a test point (capacitive), cable jacket sealing and/or shield grounding kit, compression copper lug, and bi-metallic compression lug

25k/28kV

elastimold200A25elbow.png cooper200A25elbow.png cooper200A25Posibreakelbow.png hubbell200A25elbow.png
Elastimold Cooper Cooper PosiBreak Hubbell

35kV

elastimold200A35elbow.png cooper200A35elbow.png hubbell200A35elbow.png
Elastimold Cooper Hubbell

200ALBElbowPic.png[1]

Drawings

200ALBElbow.jpg [2]

Note: the drawing shows an elbow with a jacket seal kit. This will prevent the ingress of moisture under the jacket which could cause corrosion of the neutral conductor.

Manufacturers

Voltage (kV) Test Point Integral Jacket Seal Manufacturer Manufacturer Number (Housing) Other Characteristics
15 No No Elastimold 161LR  
15 No No Elastimold 165LR (Obsolete)  
15 No No Cooper LE215  
15 No Yes Elastimold 161LRJS  
15 No Yes Elastimold 165LRJS (Obsolete)  
15 No Yes Cooper LEJ215  
15 Yes No Elastimold 162LR  
15 Yes No Elastimold 166LR (Obsolete)  
15 Yes No Cooper LE215___T  
15 Yes Yes Elastimold 162LRJS  
15 Yes Yes Elastimold 166LRJS (Obsolete)  
15 Yes Yes Cooper LEJ215___T  
25/28 No No Elastimold 261LR  
25 No No Elastimold 275LR (Obsolete)  
25 No No Cooper (P)LE225  
25/28 No Yes Elastimold 261LRJS  
25 No Yes Elastimold 275LRJS (Obsolete)  
25 No Yes Cooper (P)LEJ225  
25/28 Yes No Elastimold 262LR  
25 Yes No Elastimold 276LR (Obsolete)  
25 Yes No Cooper (P)LE225___T  
25/28 Yes Yes Elastimold 262LRJS  
25 Yes Yes Elastimold 276LRJS (Obsolete)  
25 Yes Yes Cooper (P)LEJ225___T  

25kV 1/0 AL/CU Elastimold 262LR-C5240
25kV 1/0 AL/CU Raychem ELB-25-210C10
25kV 1/0 AL/CU Cooper LE225CCO6T

References

  1. Transmission & Distribution Material Stock Catalog, Chelan County PUD, 4/25/2012
  2. Underground Construction Standard, National Grid ST. 44.00.001, 2007